Air-Cooled Screw Chillers 50Tons

Air-Cooled Screw Chillers 50Tons

  • Capacity Range: 32 to 400 tons;
  •  Refrigerant: R-407C, R-134a
  • Compressor Design: semi-hermetic screw, Bitzer/Refcomp/Hanbell available.
  • Capacity Control: Stepless control or multi-steps control
  • Energy Efficiency Rating (EER):9.8~11.6, COP 2.9~3.4
  • Power Supply: 380~415V/3PH/50Hz
Categories: Tags:
  • 描述
  • Specifications
  • Application
  • Global Tab

Air Cooled Screw Chillers

Capacity Range: 32 to 400 tons;

Refrigerant: R-407C, R-134a

Compressor Design: semi-hermetic screw, Bitzer/Refcomp/Hanbell available.

Capacity Control: Stepless control or multi steps control

Energy Efficiency Rating (EER):9.8~11.6 , COP 2.9~3.4

Power Supply: 380~415V/3PH/50Hz

 

Air Cooled Screw Chiller
ModelLALC-120S2FLALC-150S2FLALC-170S2FLALC-200S2FLALC-240S2F
RefrigerantR407CR134aR407CR134aR407CR134aR407CR134aR407CR134a
Rated Cooling Cap.kW112113129131159178185191216218
Tons31.8232.1036.6537.2245.1750.5752.5654.2661.3661.93
Comp. Input PowerCooling  kW3431.742.235.54947.754.850.663.557.8
Power Supply380V /3PH /50Hz  (Check for 60Hz)
Safety Devices Phase reversion protection, phase loss protection, overcurrent protection, discharge temperature protection, high and low pressure protection, low-temperature protection, water flow protection
Refrigerant Circuits1111111111
Capacity Control %Stepless Capacity Control        or       0,50,75, 100
Control ModeMicrocomputer Control
Refrigerant Charge27273132384345465253
CondenserCopper tubes with hydrophilic corrugated aluminum fins
EvaporatorTypeShell and Tube
Maximum pressure MPa1
IN/OUT pipe inch2 1/2"2 1/2"2 1/2"3"3"
CW IN/OUT Temp. ℃12/712/712/712/712/7
Water flow  m3/h19.319.422.222.527.330.631.832.837.137.5
Pressure Drop KPa28333338
Condensing FanTypeAxial  Type42
Air Volume m3/h56800568008140085200122100
Fan power qty1.13*41.13*41.85*41.13*61.85*6
Operation Noise dB(A)83778577857885788579
Unit Weight(kg)10101450178021302540
Operation Weight(kg)11101600196023402620
Unit dimensions(L*W*H)2250*2100*23002250*2100*23002250*2100*23003400*2100*23003400*2100*2300
Note: The above data are gotten under the following testing conditions:
1. Nominal cooling capacity: ambient air DB/WB 35℃/24℃,inlet/outlet chilled water 12/7℃, fouling factor 0.088 m2 ℃/kW;
2. Chilled water temperature range 5~15℃(R407C),  5~20℃(R134a);
3. Ambient Temperature: 15~43℃(R407C), 20~50℃(R134a).
4. The specifications may have some changes due to product improvement without notice.
  1. Typical applications include schools, hospitals, hotels, and offices.
  2. Air conditioning for medium to large scale facilities.
  3. Process cooling at factory, manufacturing operations
  4. Data Center
Online Service