Heat Recovery Water Cooled Chiller 600kW~1000kW

Heat Recovery Water Cooled Chiller 600kW~1000kW

Heat Recovery Water Cooled Screw Type Chiller  R407C

  1. Cooling capacity range: 600 -1000 kW ( 170-284 TR);
  2.  COP 4.1 ~ 4.98; Can reach more than 6 for flooded chiller
  3. Shell and Tube type Condenser;
  4. Shell and Tube Evaporator, optiontal Heat Recovery Condenser;
  5. 10 years proven touch screen control boards, BMS compatible with RS485;
  6. Free hot water supplying system.
  7. Heavy gauge support Plates;
  • Description
  • Specifications
  • Structure
  • Global Tab

CWL Water Cooled Screw Chiller  600~1000kW, R22/R407C

Features:

1. Cooling capacity range from 98KW to 3167KW;

2. Refrigerant: option for R22, R407C, R134A, R404A

3. Hanbell screw compressor, 50000-80000 hours defect free;

4. High efficiency Shell and Tube Condenser and Evaporator;

5. Option for heat recovery unit, which could provide 55oC hot water for free to end user;

6. Danfoss/ Alco Expansion Valve;

7. Option for DDC and PLC control;

8. BMS compatible with RS485;

9. 10 years proven touch screen control boards;

10. Stable quality, long operating life time.

11. Standard is 380V/3PH/50Hz, different power supply available.

Specifications of Heat Recovery Type Water Cooled Screw Chiller

CWL Series Water Cooled Screw Type Heat Recovery Chiller(Two Circuits)
Model  CWL~(N)560WDB660WDB780WDB920WDB980WDB
RefrigerantR22R407CR22R407CR22R407CR22R407CR22R407C
Rated Cooling

Cap.

×1000 kcal/h531.2513.7614.3593.4732.0699.9871.3828.3919.8874.4
kW618597714690851814101396310701017
USRT175.7169.9203.1196.2242.0231.4288.1273.9304.2289.1
Heat Reciaimed

Capacity

×1000 kcal/h159.4154.1184.3178.0219.6210.0261.4248.5275.9262.3
kW185179214207255244304289321305
USRT52.751.060.958.972.669.486.482.291.286.7
Input PowerkW119.7115.0138.7134.1168.2160.7195.3186.2206.2196.7
Operating current  A211.8203.4245.4237.4297.6284.4345.6329.6365.0348.0
Power Supply3φ-380~415V /50Hz
Safety DevicesPhase reverse protection, lack phase protection,over current protection,

discharge temperature protection, high and low pressure protection, low

temperature protection, water flow protection,etc

Refrigerant Circuits22222
Energy Control  %0,25,37.5,50,62.5,75,87.5,100
Refrigerant Charge  kg116130156190196
Condenser  Shell and Tube Type
Water Side Max Pressure (Mpa)1
Condenser Inlet/Outlet

Pipe Size  in

5″4″×24″×25″×25″×2
Cooled Water Flow  m3/h126.8122.5146.7141.7175.3167.6207.8197.7219.4208.7
Condenser Press.Drop  KPa49494949505049495050
Evaporator  Shell and Tube Type
Water Side Max Pressure (Mpa)1
Evaporator Inlet/Outlet

Pipe Size  in

5″5″6″6″6″
Chilled Water Flow m3/h106.2102.7122.9118.7146.4140.0174.3165.7184.0174.9
Evaporator Press.Drop  KPa51514444464647474747
Heat Recoverer Inlet/Outlet

Pipe Size  in

2-1/2″2-1/2″2-1/2″3″3″
Water Side Max Pressure (Mpa)1
Sanitary hot water flow  m3/h31.930.836.935.643.942.052.349.755.252.5
Heat Recoverer Press.Drop  KPa27272929343434343434
Operation Noise  dB(A)7171727272
Unit weight  kg34203700388041304340
Run weight  kg42804750495052805520